Silicone water repellent in an aqueous emulsion, for chemical barriers
Solution of special modified silicone resins, dispersed in water, hydrophilic in the application phase, water-repellent and water-repellent after reaction with atmospheric carbon dioxide, for the preparation of water-repellent solutions for the creation of chemical barriers against capillary rising in masonry.
Components
Single-component
Appearance
Liquid
Customs code
3824 9970
Request product info
Lines of belonging
Thematic site
Where it is used
How to use
Technical data
Additional content
Warnings and precautions
Media
Related products
Fields of application
Formation, by injection, of horizontal chemical barriers for stopping capillary rising damp in building renovation and damp brickwork; water repellent and reinforcing treatment with slightly alkaline porous building materials: bricks, tiles, terracotta and crude ceramic materials, etc.
Allowed supports
Bricks
Tuff
Mixed walls (bricks and stones)
Stone walls
Preparation of supports
Remove the existing plaster, only if necessary, up to at least one metre above the line of evident damp.
Draw a line parallel to the outside kerb or inside flooring, at a distance of about 10-15 cm from the same. Prepare drilling points at 12 cm distance from one another on the traced line. The inclination of the holes should be about 20ยฐ down. The depth of the holes should be approximately 4/5 the thickness of the wall to inject. The drill bit to be used must have a diameter of 18-20 mm. Once the holes are finished, the dust produced by drilling is required to be eliminated.
Mode of use
The product can be diluted with demineralised water or with a hardness less than 35ยฐF up to a maximum of 15-20% (it is recommended for use preferably without dilution). Proceed with the pure product or with the solution obtained, with low pressure injections by airless pump (manual or electric), directly into the designated holes in the masonry.
Consumption may vary depending on the characteristics of the masonry and its thickness. By way of example, for 50 cm thick masonry, the indicative consumption of the aqueous solution is between 17 and 20 l/m.
Consilex Barrier-A requires an adequate and as lengthy an exchange as possible with the atmosphere, for the hydrophilic-hydrophobic transformation: schedule an adequate waiting time prior to sealing the injection holes and coating the brickwork. It is advisable to create the chemical barrier with Consilex Barrier-A- when work commences at the construction site and to close the injection holes a few days before ends.
Apply on porous media, with pH not exceeding 8.
Protect glass and aluminium surfaces from contact with the product.
Application methods
Injection
Low pressure airless nebulizer
Tool cleaning
Water
Key features
Density: 1.02 kg/dmยณ
Nonflammable
Shelf-life: 12 months
Solvent-free
Use wearing protective glasses
Use wearing protective gloves
Technical specifications
Consumption
From 3.5 to 4.0 litres of Consilex Barrier-A per linear metre of 10 cm thick masonry. Calculate the consumption in proportion to the thickness of the masonry to be restored.
Available colors
Transparent
Packaging and dimensions
Plastic can 10 l
Plastic can 25 l
Plastic can 5 l
Storage and conservation
Protect from freezing.
Additional content
Alternative uses of the product
The product can also be used effectively as water repellent treatment of masonry surfaces in general. In this case, apply the product as it is on dry porous media. Protect the treated surfaces from rain in the hours immediately following application.
Warnings
The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.
Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.
The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.
Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
It is forbidden to dispose of the product and/or packaging in the environment.
Intellectual property rights related to all the artistic, literary, and photographic content of this website are reserved. Its reproduction and use in any form or by any means, electronic or mechanical, including photocopies, recordings, transmissions, or any other information storage and retrieval system, are prohibited.