Fields of application
Structural restoration, dimensional adjustments, reinforcements, high dimension anchorages, drawing and armouring works, etc., by pumped or poured casting installation. Realisation of structural road joints.
Allowed supports
Concrete
Prefabricated concrete
Mixed walls (bricks and stones)
Rusty reinforcement rods
Preparation of supports
Application surfaces should be clean, free of soiling, crumbling and non-adhering parts, dust, etc., conveniently saturated with water until they reach the condition "saturated with dry surface". An adequate roughening of the surfaces by scarifying, sandblasting etc. is always necessary in order to obtain the maximum adhesion values to the substrate. The optimal values are obtained with high pressure hydro-scarification. Bare the irons undergoing disruptive oxidation or deeply oxidized, removing the rust of the exposed irons (by sandblasting or abrasive brushes).
Mode of use
Insert 2/3 (approximately 2.5 litres per bag) of the total mixing water in the cement mixer, then gradually add the product and the remaining water, mix until a homogeneous lump-free mixture of the desired consistency is obtained.
For high anchoring sections Ghiaietto 6.10 should be added (please refer to the appropriate technical data sheet for more information).
Technical specifications
Compressive strength after 1 day
UNI EN 12190
> 30 N/mmยฒ
Compressive strength after 7 days
UNI EN 12190
> 60 N/mmยฒ
Compressive strength after 28 days
UNI EN 12190
> 80 N/mmยฒ
Flexural strength at 1 day
UNI EN 196/1
> 5 N/mmยฒ
Flexural strength after 7 days
UNI EN 196/1
> 9 N/mmยฒ
Flexural strength after 28 days
UNI EN 196/1
> 11 N/mmยฒ
Resistance to carbonatation
UNI EN 13295
0.5 mm
Resistance to the extraction of the steel bars with improved adhesion
> 30 MPa
Skid resistance
UNI EN 13036-4
50 mm
Capillary absorption
UNI EN 13057
0.49 kgโขh^0.5/mยฒ
Water penetration under pressure (5 bar for 72 hours)
UNI EN 12390-8
< 5 mm
Chloride content
UNI EN 1015-17
< 0.01 %
Determination of thermal compatibility
UNI EN 13687-1
โฅ 2 mPa
Thermal conductivity
UNI EN 12664
0.82 W/mK
Concrete adhesion (cutting test)
> 5 MPa
Reaction to fire
EN 13501-1
A1
Static elastic modulus
EN 13412
30000 N/mmยฒ
Consumption
Approximately 19,50 kg/mยฒ of Grout 6 for every centimetre of thickness to be implemented (approximately 1950 kg per cubic metre).
Packaging and dimensions
Bag 25 kg
Pallet: 50 x (Bag 25 kg)
Storage and conservation
Store the product in its original packing, in a fresh and dry environment, avoiding frost and direct sunlight.
Warnings
Given the self-levelling properties of the product and its self-compacting properties, it is recommended to pay special attention to the vibration step. A excessive zeal in the vibration operation can worsen the aesthetic appearance of the resulting product.
Do not use in the absence of adequate lateral confinement.
Cure the protection and the moist hardening of exposed surfaces.
Adopt casting procedures capable of ensuring the absence of gaps and discontinuities, pouring the mortar from a single part of the casting perimetre to avoid air pockets.The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.
Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.
The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.
Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
It is forbidden to dispose of the product and/or packaging in the environment.