Ringseal L19
The hydro-expansive capacity of RINGSEAL Lยญ19 has been tested in the laboratory with three different types of water: demineralised water, salt water and water with strongly basic Ph (to simulate the conditions in contact with the concrete). The expansion tests showed a change in volume ranging from a minimum of about 200% (three times the initial volume) in the case of salt water to a maximum in excess of 900% in the case of demineralised water.
In the standard version, the seal RINGSEAL Lยญ19 is sized for the usual measures of the blade caisson spacers, normally used in the construction industry: in this case with a width of about 20 mm, in the version straight/flat or "twisted" (designed to minimise the propensity to form deformities during the pouring of the concrete in the formwork).
Fields of application
Subterranean construction of concrete by formwork in wood, where the wall is in direct contact with the ground and where there is the presence of waterproofing layers external to the masonry itself: basements, cellars, underground garages, underground environments and basements, etc.
Allowed supports
Concrete
Metallic spacers for wooden formworks
Mode of use
Place the hydro-expansive seal RINGSEAL Lยญ19 with the appropriate dilating pliers in central position with respect to the length of the blade caisson spacers (one seal for each spacer). Build the planned formwork using the metal spacer for wooden formworks thus prepared and proceed with the usual operations of casting the concrete.
Application methods
Apply by hand
Dilating pliers
Consumption
No. 1 Ringseal L19 gasket for each "blade" formwork spacer (average 6 - 8 pieces per square metre for wooden formworks of 2 x 0.5 metres).
Storage and conservation
Store the product in its original packing, in a fresh and dry environment, avoiding frost and direct sunlight.
Warnings
The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.
Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.
The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.
Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
It is forbidden to dispose of the product and/or packaging in the environment.