The anticorrosive efficacy of Repar Steel is determined by the high alkalinity and by the superpozzolanic reaction of the components of the anhydrous system, as well as by the presence, in the liquid component (B), of migratory and interfacial corrosion inhibitors, capable of carrying out cathodic and anodic protection, based on organic compounds capable of making ferrous ions unavailable for feeding electrochemical corrosion processes. The polymeric components of the solution also determine further increases in the anticorrosive efficacy, especially against aggressive attacks deriving from chlorides and sulphates, and increase the adhesion between the treated bar and the concrete (adherence test according to EN 15184 in compliance with the UNI EN technical standard 1504 "Products and systems for the protection and repair of concrete structures - Part 7: Corrosion protection of reinforcements").
Passivating protective anti-corrosive treatment for reinforcing rods in restoration works in reinforced concrete.
Carefully remove loose rust from the metal surfaces of exposed reinforcing bars by sandblasting or deep brushing until the white metal surface is obtained. This operation is essential to effectively develop the anticorrosive property of Repar Steel. Obviously, to block the advance of the carbonation profile in the concrete, it is essential to complete the restoration with the appropriate restoration mortars: thixotropic (Repar line) or pourable (Grout line).
Mix components A and B and continue mixing until a homogeneous, lump-free mixture is obtained. Apply with a brush to the surfaces of the previously prepared reinforcing bars. To prevent the application of the repair mortar from removing the still fresh Repar Steel treatment, wait for the product to harden before proceeding with the volumetric restoration. The minimum recommended waiting time is approximately 6-8 hours with summer temperatures and approximately 12-16 hours with winter temperatures. Do not apply the product with temperatures below 5°C or if it is expected that the temperature may fall below this value during the first 12 hours of curing.
Compressive strength after 1 day
UNI EN 1015-11
Compressive strength after 28 days
UNI EN 1015-11
Flexural strength at 1 day
UNI EN 1015-11
Flexural strength after 28 days
UNI EN 1015-11
Corrosion resistance
EN 15183
Resistance to the extraction of the steel bars with improved adhesion
EN 15184
Reaction to fire
Density
UNI EN 1015-6
Adhesion to substrate
EN 1542
Capillary absorption
UNI EN 13057
From 0.03 to 0.1 kg of Repar Steel for each linear metre of steel bar to be treated.
The overflow of the product on the concrete adjacent to the treated rids does not entail any problem.
The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.