Beltseal
The hydroexpansive capacity of Beltseal has been laboratory tested with two different types of water: demineralised and with a highly basic pH (to simulate conditions in contact with concrete). Expansion tests showed a respective change in volume of 300% and 250%.
Fields of application
For underground concrete constructions with conduit pipes, where the wall is in direct contact with the ground and where there are no layers of waterproofing outside the masonry itself: basements, cellars, underground garages, below-ground and cellar environments, etcetera.
Allowed supports
Concrete
Prefabricated concrete
Plastic
Steel
Mode of use
Position the Beltseal hydrofoam gasket centrally in respect of the length of the pipe (using one gasket per pipe).
Technical specifications
Alkali-resistant material
Breaking load longitudinal
>1.5 MPa
Longitudinal elongation at break
>350 %
Resistance to water pressure
5 bar
Consumption
No. 1 Beltseal gasket for each conduit pipe to be sealed.
Packaging and dimensions
Beltseal 70/90: 1 x (Box 180 unit)
Beltseal 110/125: 1 x (Box 180 unit)
Beltseal 160/200: 1 x (Box 180 unit)
Storage and conservation
Store the product in its original packing, in a fresh and dry environment, avoiding frost and direct sunlight.
Warnings
The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.
Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.
The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.
Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
It is forbidden to dispose of the product and/or packaging in the environment.