Protech Fix AC - Therm zoom
Protech Fix AC - Therm image 1
Protech Fix AC - Therm image 2
Protech Fix AC - Therm image 3

Protech Fix AC - Therm

Anti-condensation reinforcing acrylic fixative, in aqueous dispersion

Water-based anti-condensing wall covering, with excellent fixing and anchoring properties, with good coverage based on high penetration acrylic resins, 3M Glass Bubble, pigments, fillers and covering fillers. Suitable as an anti-condensation fixative primer, prior to painting or coating the plaster with anti-condensation paints or plasters (-THERM).
Components
Single-component
Appearance
Thick liquid
Customs code
3209 1000

Request product info

    By submitting I agree to the privacy notice

    Lines of belonging
    Linea prodotto Building
    Thematic site
    Sanawall
    Features and benefits
    Where it is used
    How to use
    Technical data
    Additional content
    Warnings and precautions
    Media
    Related products

    Protech Fix AC - Therm

    Ideal for interventions on walls with mucilage deposits, bacterial phenomena and moulds. Due to its low thermal conductivity, it is particularly suitable for solving mould problems. It can be applied on any plaster (rustic, civil, plaster, dry mortar, plasterboard, concrete, prefabricated, exposed concrete, etc.).
    Made with special resins and additives it reduces the absorption of the support while allowing the necessary transpiration, uniforms the absorption making the application of the finishing coats easier. It always works in depth, which is why it is the ideal preparation for applying water-based paints or coatings. Adhesion is excellent even on particularly difficult surfaces, thanks to the use of special resins and the presence in the formulation of an adhesion promoter interacting between the support and the product.

    Fields of application
    Preliminary treatment of any surface (civil, plaster, rustic, dry mortars, plasterboard, concrete, prefabricated, exposed concrete etc.) designed to isolate the support surfaces and standardise the absorptions of the subsequent anti-condensate treatments (painting and protective coatings).
    Allowed supports
    Plasters
    Concrete
    Cement-based or lime-based mortars
    Prefabricated concrete
    Drywall
    Plaster (gypsum)
    Preparation of supports
    For new surfaces remove any dust, while for old surfaces remove any non-adherent paint, scrape, brush until you find the sound part of the substrate. Any fungi and moulds must be carefully brushed and disinfected with Consilex Muffa Cleaner and Consilex Muffa Remover. After a few hours, when the microorganisms have neutralized, carefully clean, then proceed with the application of a coat of Protech Fix AC - Therm.
    Mode of use
    It can be applied by brush or roller by diluting the product from 20% to 50% with water. During the application, cover the areas not to be painted well, spread evenly avoiding dripping and wait 4-6 hours for subsequent applications. Ideal as an anti-condensation base for false ceilings and insulated plasterboard false walls.
    Application methods
    Low pressure airless nebulizer
    Brush
    Paint roller
    Sprayer
    Tool cleaning
    Water
    Key features
    Density
    Density: 1.32 kg/dmยณ
    Highlighted product
    Highlighted product
    Shelf-life
    Shelf-life: 12 months
    Solvent-free
    Solvent-free
    Temperature of use
    Temperature of use: +5 / +35 ยฐC
    To be applied in two coats
    To be applied in two coats
    Technical specifications

    Time before second coat at 20ยฐC
    20 ยฐC

    4 - 6 h
    Consumption
    From 0.10 to 0.15 litres of Protech Fix AC-THERM for each square metre of surface to be treated, based on the porosity of the support.
    Available colors
    White
    Packaging and dimensions
    Pail 14 l
    Storage and conservation
    Protect from freezing.
    Additional content

    Warnings
    To avoid film-formation defects, being resin-based products in aqueous emulsion, the application temperature must be between + 5ยฐC and + 35ยฐC with relative humidity not exceeding 60/70%. Do not apply under direct sunlight or wind.The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
    Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.

    Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
    Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.

    The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.

    Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
    It is forbidden to dispose of the product and/or packaging in the environment.
    Photo gallery
    Technical Documentation
    Key features

    Request product info

      By submitting I agree to the privacy notice

      Copyright ยฉ 2024 All Rights Reserved
      Powered by Webplease
      magnifiercross