Anti-condensation siloxane paint, sanitizing, heat-reflecting

Anti-condensation, elastic, sanitizing, heat-reflecting paint, with hollow glass microspheres (3M Glass Bubble), ideal for both external and internal facades, based on siloxane resin in emulsion, with high permeability to water vapor and with excellent covering power. Recommended as a breathable, water-repellent protective finish for macroporous dehumidifying plasters (Sanatigh, Sanawarme, Caleosana).
Components
Single-component
Appearance
Customs code
3209 9000

Request product info

    By submitting I agree to the privacy notice

    Lines of belonging
    Linea prodotto Building
    Linea prodotto Opus
    Linea prodotto Sanageb
    Thematic site
    Opus DrySanawall
    Features and benefits
    Where it is used
    How to use
    Technical data
    Additional content
    Warnings and precautions
    Media
    Related products

    Protech Sil P - Therm

    Protech Sil P - Therm is a paint suitable for any type of mineral substrate, such as old and new plasters, synthetic plasters, sandstone walls, etc. For old emulsion paints, remove non-adherent parts, remove any impurities, repair any cracks or crevices and then consolidate everything with Protech Fix AC - Therm, a silicon water repellent fixative primer, also suitable for highly alkaline substrates.
    Protech Sil P - Therm has excellent covering power: class 1 according to EN 13300 for a yield of 6/7 m2/l.

    Fields of application
    In addition to the painting of external facades and internal environments, Protech Sil P-THERM has been designed especially for buildings and monuments subject to the protection of the ministry of cultural heritage. The binder based on an emulsion of silicones has allowed to develop a microporous filter impermeable to heavy rain, and at the same time permeable to the diffusion of water vapour. The great advantage of this paint is that it can be applied both on mineral (inorganic) supports and on previously treated supports with emulsion-based paints, creating a physical adhesion, with extremely microporous films. The particular chemical structure of the silicone binder produces a film resistant to light and atmospheric agents that is not destroyed even by microorganisms.
    Allowed supports
    Plasters
    Concrete
    Cement-based or lime-based mortars
    Prefabricated concrete
    Drywall
    Plaster (gypsum)
    Fiber-cement
    Preparation of supports
    For old emulsion paints, remove non-adherent parts, remove any impurities, repair any cracks or crevices and then consolidate everything with Protech Fix AC - Therm, a silicon water repellent fixative primer, also suitable for highly alkaline substrates.
    SUPPORTS ALREADY PAINTED WITH SILICATE PAINT
    Remove any stains and proceed with painting with the siloxane paint. (it is always recommended to apply a coat of siloxane impregnating agent).
    NEW SUPPORTS
    Apply a coat of siloxane acrylic fixative diluted from 20 to 60% with water depending on the absorption of the support.
    OLD SUPPORTS
    On old supports, remove the old paint by brushing, fill in any holes or imperfections in the wall with a suitable filler, proceed with fixing with siloxane impregnating agent diluted 20 to 60% with water depending on the absorption of the support.

    Mode of use
    DILUTION (in volume with potable water)
    1st COAT:
    BRUSH: 15% one coat crossed or two coats 12-24 hours apart
    ROLLER: 10%
    SPRAY (with specific equipment): 15 - 25%
    2nd COAT
    BRUSH: 10%
    ROLLER: 10%
    SPRAY (with specific equipment): 15 - 25%

    On large surfaces, it is recommended to apply the product of the same lot and proceed always wet on wet to avoid signs of resumption. Never operate at temperatures below + 5ยฐC. Rainy weather, excessive atmospheric humidity and temperatures below + 8ยฐC, can considerably compromise drying with the possibility of rainwater washout even after several days. In these situations, it is advisable to protect the facades from unpredictable showers, in order not to jeopardize the success of the work. For storage store in tightly closed containers and protect from frost.

    Application methods
    Low pressure airless nebulizer
    Brush
    Paint roller
    Sprayer
    Tool cleaning
    Water
    Key features
    Density
    Density: 1.62 ยฑ 0.05 kg/dmยณ
    Dosage
    Dosage: 0.3 / 0.4 kg/mยฒ
    Highlighted product
    Highlighted product
    Max. recommended thickness
    Max. recommended thickness: 280 ฮผm
    Min. recommended thickness
    Min. recommended thickness: 180 ฮผm
    Shelf-life
    Shelf-life: 12 months
    Solvent-free
    Solvent-free
    Temperature of use
    Temperature of use: +8 / +30 ยฐC
    To be applied in two coats
    To be applied in two coats
    Technical specifications

    Degree of water vapor transmission

    0.06 m

    Wet abrasion resistance
    EN 13300

    2

    Solar reflection index (SRI)
    ASTM E1980-11

    108

    Touch hardening at 20ยฐC

    1 - 2 h

    Deep hardening at 20ยฐC

    16 - 24 h

    Dust-free time at 20ยฐC

    30 min

    0.10

    Permeability to water vapor

    115 ฮผ
    Consumption
    Apply from 0.20 to 0.30 kg of Protech Sil P-THERM per square metre of surface to be painted.
    Available colors
    White
    Cartella colori Azichem - silossanici
    Packaging and dimensions
    Pail 4 l
    Pail 14 l
    Storage and conservation
    Protect from freezing.
    Additional content

    Warnings
    The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
    Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.

    Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
    Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.

    The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.

    Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
    It is forbidden to dispose of the product and/or packaging in the environment.
    Photo gallery
    Technical Documentation
    Key features

    Request product info

      By submitting I agree to the privacy notice

      Copyright ยฉ 2024 All Rights Reserved
      Powered by Webplease
      magnifiercross