Sanafluens zoom
Sanafluens image 1
Sanafluens image 2
Sanafluens image 3

Sanafluens

Superfluid grout based on reinforcing, injectable hydraulic lime mortar

Powder preparation, ready-to-use, based on hydraulic lime, for the preparation, with the sole addition of water, of grout for masonry reinforcement, injectable and castable, high performance in terms of sliding, strength and stability, for ecological building interventions and the restoration of vintage buildings and monuments.
Components
Single-component
Appearance
Powder
Customs code
3824 5090

Request product info

    By submitting I agree to the privacy notice

    Obtained Certifications and Regulations
    EN 998-1EN 998-2M20
    Lines of belonging
    Linea prodotto Opus
    Linea prodotto Sanageb
    Thematic site
    Grout PowerSanageb
    Features and benefits
    Where it is used
    How to use
    Technical data
    Warnings and precautions
    Media
    Related products

    Sanafluens

    In the Sanafluens mixtures, the water is completely and stably incorporated from the hydration reaction of lime; conversely, in traditional mixtures, a very high part of added water, is free, and evapourating, it leaves gaps in the walls. Sanafluens is based on natural hydraulic lime, sodium gluconate, kaolin, aluminates; it does not contain cement, resins, solvents and radioemissive aggregates.


    Fields of application

    Consolidation through injections of brick, stone or mixed masonry, "bag" structures, masonry damaged by the earthquake. Consolidation of masonry affected by capillary rising damp and soluble salts. Consolidation of plasters detached from the masonry support, even with frescoes or of historical and artistic value. Consolidation of foundation structures, pillars, vaults and arches.


    Allowed supports
    Cement-based or lime-based mortars
    Bricks
    Mixed walls (bricks and stones)
    Stone walls
    Lime and lime-cement plasters and mortars
    Preparation of supports

    Clean the application surfaces by spraying abundantly with water. If there is a lack of plaster, apply a suitable render of hydraulic lime and sand (such as Untersana) to close as much as possible the escape routes of the grout once it has been injected. Trace, from bottom to top and from left to right, a 50 cm square grid. On the intersection of the squares, drill the masonry with a rotary drill, with a bit of suitable diameter (depending on the type of masonry to be injected; diameter usually between 12 and 24 mm), to a depth of at least 3/5 of its thickness, tilting the drill downwards by about 10 - 20°. Once all the holes have been drilled, they will be sucked up, blown with compressed air and sprayed with water, to remove the dust inside them produced by the drilling. Insert in the holes for a depth of about 5 cm, transparent meshed rubber tubes, with a total length of at least 30 cm (therefore with about 25 cm external). Properly seal the perimeter of the pipe with Anchorsana Fix accelerated setting grouting mortar to prevent the injected product from escaping. Inject the grout always keeping it lightly mixed and operating a continuous flow, without interruptions.


    Mode of use

    Pour about 2/3 of the mixing water into the mixer. Gradually add Sanafluens and the water still required, continue to mix until a fluid, homogeneous, lump-free grout of the desired consistency is obtained. The mixing water indicatively necessary is equal to 22-24% by weight (5.5 - 6 litres per bag). Reinforcing backfills and fills can be carried out both by gravity and using manual or automatic pumps, depending on the type of application. To verify the effectiveness of the reinforcement, the grout will come out of the pipes adjacent to that in which it is injected.


    Application methods
    Pour out
    Injection
    Pump
    Tool cleaning
    Water
    Key features
    Dosage
    Dosage: 1.50 - 1.55 kg/dmยณ
    Mix with water
    Mix with water: 22-24 %
    Pot-life
    Pot-life: 60 min
    Shelf-life
    Shelf-life: 12 months
    Temperature of use
    Temperature of use: +6 / +30 ยฐC
    Technical specifications

    Compressive strength
    UNI EN 1015-11

    > 20 N/mmยฒ

    Flexural strength
    UNI EN 1015-11

    > 6 N/mmยฒ

    Permeability to water vapor
    EN 1745

    15/35 ฮผ

    Capillary absorption
    UNI EN 1015-18

    0.53 kgโ€ขh^0.5/mยฒ

    Density
    UNI EN 1015-6

    1980 kg/mยณ

    Chloride content
    UNI EN 1015-17

    0.0082 %

    Water penetration after capillary absorption
    UNI EN 1015-18

    2.4 mm

    Bonding force
    UNI EN 1015-12

    1.2 N/mmยฒ

    Thermal conductivity
    EN 1745

    0.67 W/mK

    Static elastic modulus

    12000 MPa
    Consumption

    Approximately 1500 kg of Sanafluens for each cubic metre of volume to be filled.

    Available colors
    Gray
    Packaging and dimensions
    Bag 25 kg
    Pallet: 50 x (Bag 25 kg)
    Storage and conservation
    Store the product in its original packing, in a fresh and dry environment, avoiding frost and direct sunlight.
    Warnings

    An abundant preliminary injection of water into the holes drilled in the masonry is recommended, to allow an adequate and rapid sliding of the grout.

    The general information, along with any instructions and recommendations for use of this product, including in this data sheet and eventually provided verbally or in writing, correspond to the present state of our scientific and practical knowledge.
    Any technical and performance data reported is the result of laboratory tests conducted in a controlled environment and thus may be subject to modification in relation to the actual conditions of implementation.

    Azichem Srl does not assume any liability arising from inadequate characteristics related to improper use of the product or connected to defects arising from factors or elements unrelated to the quality of the product, including improper storage.
    Those wishing to utilise the product are required to determine prior to use whether or not the same is suitable for the intended use, assuming all consequent responsibility.

    The technical and characteristic details contained in this data sheet shall be updated periodically. For consultation in real time, please visit the website: www.azichem.com. The date of revision is indicated in the space to the side. The current edition cancels out and replaces any previous version.

    Please note that the user is required to read the latest Safety Data Sheet for this product, containing chemical-physical and toxicological data, risk phrases and other information regarding the safe transport, use and disposal of the product and its packaging. For consultation, please visit: www.azichem.com.
    It is forbidden to dispose of the product and/or packaging in the environment.
    Photo gallery
    Technical Documentation

    Request product info

      By submitting I agree to the privacy notice

      Copyright ยฉ 2024 All Rights Reserved
      Powered by Webplease
      magnifiercross